Reliability of Peak Expiratory Flow Rate Versus FEV₁ Reversibility in Assessing Bronchodilator Response in Asthma: A Cross-Sectional Study

Main Article Content

Vignesh Nagalingam, Nethra Dinakaran, Prasanth Gururaj, Swetha Sasikumar, Anbumaran Parivakkam Mani

Abstract

Background: Background: Peak expiratory flow rate (PEFR) is cheap and portable, but it is unclear whether PEFR reversibility can replace FEV₁ reversibility when assessing bronchodilator response in asthma.
Objective: To compare bronchodilator response measured by PEFR with that measured by FEV₁ spirometry, and to assess the diagnostic accuracy of PEFR against an FEV₁ reference standard.
Objective: To compare bronchodilator response measured by PEFR with that measured by FEV₁ spirometry, and to assess the diagnostic accuracy of PEFR against an FEV₁ reference standard.
Methods: In this cross-sectional study at a tertiary hospital in Chennai (January–June 2025), 120 stable patients with asthma aged 8–63 years underwent spirometry and peak flow measurement before and 15–20 minutes after salbutamol 200 mcg by metered-dose inhaler with spacer. A significant FEV₁ response was defined as an increase of ≥12% and ≥200 mL.
Results: Mean age was 35.7 ± 14.1 years and 76 patients (63%) were female. FEV₁ rose from 1.64 ± 0.70 L to 1.84 ± 0.71 L (mean change 0.20 L, 95% CI 0.17–0.23; 15.0 ± 12.4%). PEFR rose from 295.3 ± 124.6 to 334.8 ± 120.6 L/min (mean change 39.5 L/min, 95% CI 35.8–43.2; 16.3 ± 10.4%); both changes had p < 0.001. Percentage reversibility in PEFR correlated only weakly with that in FEV₁ (r = 0.27, p = 0.04). Forty-two patients (35%) met the FEV₁ criterion. A PEFR increase of ≥15% detected them with sensitivity 52% (95% CI 32–72) and specificity 62% (95% CI 46–75); the area under the ROC curve was 0.53.
Conclusion: Both PEFR and FEV₁ rise after bronchodilator in asthma, but PEFR reversibility agrees poorly with FEV₁ reversibility in this sample. PEFR should not replace spirometry for bronchodilator reversibility testing, although larger studies are needed.

Article Details

Section
Articles