External Validation, Calibration, and Equity of Artificial Intelligence Early Warning Models for Clinical Deterioration in Hospitalized Patients: A Systematic Review and Exploratory Meta-Analysis
Main Article Content
Abstract
Background: Evaluation of a deterioration model in a new institution is not the same as internal validation and discrimination alone does not establish reliable risk estimates, fair performance or better outcomes. These differences are particularly relevant when the development provenance of proprietary scores is not disclosed.
Objective: To describe geographic external-validation evidence for data-derived inpatient deterioration models; calibrate and sociodemographic equity reporting; and perform narrowly defined exploratory synthesis when compatible model-specific data were available.
Methods: Europe PMC was searched until 3 September 2026 with two fully paginated queries; one AI assistant screened, assessed reports and extracted data; provisional PROBAST+AI-informed domain appraisal without independent duplicate review was performed only once. Eligible primary reports tested a fixed model in geographically separate institutions among adult general acute-care inpatients initially free of target event. Commercial models with unverifiable training site overlap and dedicated equity/implementation reports were synthesized separately. AUROCs from seven external M-CURES evaluation cohorts in one report were synthesized on the logit scale using restricted maximum likelihood and modified Hartung–Knapp intervals.
Results: The search returned 1,765 records; after removing 44 identifier duplicates there were 1,721 lefts. After title and abstract screening, we sought 110 reports; 27 weren’t obtained and 83 were assessed. Thirty-four reports remained (18 geographic-validation confirmed reports, 13 provenance-unverified commercial score evaluations, three equity/implementation context reports). These are report counts not independent studies or unique populations counts. No overall total participant count was calculated because reports overlapped with institutional cohorts. For M-CURES seven external cohorts had 8335 admissions and 1304 qualifying events across 12 medical centers. Exploratory pooled AUROC was 0.811 (95% CI 0.787–0.834), I² 45.7%, 95% prediction interval 0.757–0.856. Calibration and equity results were not sufficiently standardized for quantitative synthesis.
Conclusions: The retrieved evidence supports model-specific assessment not overall “AI early-warning accuracy.” Geographic validation did not establish calibration, fairness or clinical effectiveness; the M-CURES synthesis only reports site-grouped performance in one coordinated report and should not be read as seven independent replications nor generalized to other deterioration models; single index coverage, unavailable reports and single assistant assessment substantially reduce confidence and require human verification before clinical/publication use.