Comparison of Frictional Forces of Two Different Brands of Rhodium-Coated Arch Wires with Ceramic Brackets – an in vitro study
Main Article Content
Abstract
Background: Resistance to sliding at the bracket–archwire interface influences orthodontic tooth movement and treatment efficiency. Rhodium-coated nickel–titanium (NiTi) archwires provide improved aesthetics while maintaining the mechanical properties of conventional NiTi wires. However, evidence comparing the frictional behavior of commercially available rhodium-coated NiTi archwires remains limited. This in vitro study compared the frictional characteristics of two commercially available rhodium-coated NiTi archwires used with polycrystalline ceramic brackets.
Methods: Sixteen 0.016-inch rhodium-coated NiTi archwires were divided into two groups (n = 8): ICONIX Aesthetic Archwire and Tomy Pak White Wire. Specimens were tested with 0.022-inch MBT polycrystalline ceramic brackets using a customized Perspex jig mounted on a Universal Testing Machine. Displacement at break, force at break, tensile displacement, tensile strain, and tensile stress were recorded. Data were analyzed using an independent-samples t-test (p < 0.05).
Results: No significant differences were observed between the groups in displacement at break, tensile displacement, or tensile strain (p > 0.05). However, the Tomy Pak Wire exhibited significantly greater breaking force and tensile stress than the ICONIX Aesthetic Archwire (p < 0.05), indicating differences in friction-related mechanical performance between the two archwires.