Development and Experimental Evaluation of Bioactive Protective Coatings for Cobalt-Chromium Dental Prostheses: Effects on Corrosion Resistance, Antibacterial Activity, and Surface Biocompatibility

Main Article Content

Mohammed Saleh Alraddadi

Abstract

Background: Cobalt-Chromium (Co-Cr) alloys still define the default framework material for removable partial dentures and metal-ceramics. In addition, the patient's mouth environment, especially the medium where it is acidic, chloride, and contaminated by biofilm, may cause the passive film to be damaged and Cobalt, chromium, and molybdenum ions can be released. Moreover, alloys without alloy structures are unlikely to be capable of any antibacterial effects.
Objectives: The present study was aimed at in vitro synthesis and application of four types of bioactive protective coatings on two types of selective-laser-melted (SLM) Co-Cr-Mo alloys, with a special focus on their influence on corrosion, ion release, antibacterial and surface biocompatibility.
Methods: Polished SLM Co-Cr-Mo discs (n = 6 per assay) were kept uncoated (control) or coated by electrophoretic deposition with chitosan (CS), nano-hydroxyapatite (HA), chitosan-silver (CS-Ag), or chitosan-nano-HA-silver (CS-HA-Ag). Coatings were characterized by SEM-EDS, XRD, FTIR, roughness, contact angle, and pull off tests, and tested by potentiodynamic polarization, impedance spectroscopy in artificial saliva (pH 6.8 and 4.9), 28 day ICP-MS ion release, adhesion of Streptococcus mutans, Staphylococcus aureus, and Candida albicans, 48 h multispecies biofilm biomass, and the viability and LDH release of human gingival fibroblast (HGF) over 7 days. Data were statistically analyzed by one-way analysis of variance (ANOVA) with the Tukey's test (α = 0.05).
Results: CS-HA-Ag coating decreased corrosion current density from 85.5 ± 11.1 to 11.5 ± 1.5 nAcm-2 (pH 6.8) with a protection efficiency of 87% while increasing the polarization resistance on average 8-fold and decreasing 28-day Co, Cr and Mo release by 85%. Silver containing coatings decreased adhesion of S. mutans 3.5 log10 (CS-HA-Ag) and 3.2 log10 (CS-Ag) compared to HA alone and reduced biofilm biomass 2-fold to 8-fold (~70%). 7-day HGF viability was reduced to 81% of control for CS-Ag and increased to 111% of control for HA, while CS-HA-Ag maintained 97% of control.
Conclusion: In the limits of in vitro conditions, the Chitosan-HA-silver composite had the best compromise of corrosion protection, antibacterial and cytocompatibility (probably by the presence of hydroxyapatite). The clinical aspect and thermo mechanical behavior and longevity must, however, be evaluated

Article Details

Section
Articles